Whatsapp untuk harga: 0811 9113 330 /  0811 889 502

Buy your Medical Equipment from Authorized Agent for product quality, warranty and service.

The BiPAP A40 ventilator is intended to provide invasive and non-invasive ventilatory support to treat adult and pediatric patients weighing over 10 kg (22 lbs) with Obstructive Sleep Apnea (OSA), Respiratory Insufficiency, or Respiratory Failure. It is intended to be used in home, institutional/ hospital, and portable applications such as wheelchairs and gurneys. It is not intended to be used as a transport ventilator, and is not intended for life support.

AVAPS

Average Volume Assured Pressure Support (AVAPS) is a feature available in the S, S/T, PC, and T modes. (In AVAPS-AE mode, the AVAPS feature is always enabled.) AVAPS helps patients maintain a tidal volume (VT) equal to or greater than the target tidal volume (Tidal Volume setting) by automatically controlling the pressure support (PS) provided to the patient. The AVAPS feature adjusts PS by varying the IPAP level between the IPAP Min and IPAP Max settings (or Pressure Support Min and Pressure Support Max in AVAPS-AE mode). AVAPS will retain the learned PS for the patient so that each time therapy is started the PS will start at the learned PS. The AVAPS algorithm in the BiPAP A40 contains an improvement to more accurately achieve and maintain the target tidal volume. The muscle effort of a spontaneous breath typically results in a larger tidal volume than a machine breath delivered at the same pressure. The new AVAPS algorithm will adjust the pressure slightly on machine delivered breaths to compensate for this difference, and throughout the night, the algorithm will “learn” the correct amount of pressure adjustment to apply to machine triggered breaths. If IPAP Max is reached and the target tidal volume is not achieved, the Low Tidal Volume alarm activates (if enabled).

Product Specifications

Ventilation Modes CPAP, S, S/T, PC, T
Hybrid Ventilation AVAPS (Average Volume Assure Pressure Support)
Weight 2.1kg
Size 21.6cm W x 19cm L x 11.5 cm H
IPAP 4 - 30 cmH2O
EPAP 4 - 25 cmH2O
AVAPS rate 0.5 to 5 cmH2O / min
Inspiratory Time 0.5 - 3 sec
Target Tidal Volume 200 - 1500ml (when AVAPS enabled)
Rise Time 1 (100 ms) - 6 (600 ms)
Breathe rate 0 - 40 
Triggering & Cycling  Digital Auto-TRAK algorithm
Noise Level  < 30dBA at 10 cmH2O 
Alarms Patient disconnection, Apnea, Low minute ventilation, Low tidal volume with AVAPS only), High respiratory rate
Monitoring  Pressure, tidal volume, minute ventilation, respiratory rate, Leak, I/E
Data management Apnea/Hypopnea Index, Obstructed Airway Apnea, Clear Airway Apnea, Hypopnea, Periodic Breathing, RERA, Large Leak and Snore

 

 

 

  

Distributor Resmi - Philips.
Whatsapp untuk harga: 0811 9113 330 /  0811 889 502

Buy your Medical Equipment from Authorized Agent for product quality, warranty and service.

The BiPAP A40 ventilator is intended to provide invasive and non-invasive ventilatory support to treat adult and pediatric patients weighing over 10 kg (22 lbs) with Obstructive Sleep Apnea (OSA), Respiratory Insufficiency, or Respiratory Failure. It is intended to be used in home, institutional/ hospital, and portable applications such as wheelchairs and gurneys. It is not intended to be used as a transport ventilator, and is not intended for life support.

AVAPS

Average Volume Assured Pressure Support (AVAPS) is a feature available in the S, S/T, PC, and T modes. (In AVAPS-AE mode, the AVAPS feature is always enabled.) AVAPS helps patients maintain a tidal volume (VT) equal to or greater than the target tidal volume (Tidal Volume setting) by automatically controlling the pressure support (PS) provided to the patient. The AVAPS feature adjusts PS by varying the IPAP level between the IPAP Min and IPAP Max settings (or Pressure Support Min and Pressure Support Max in AVAPS-AE mode). AVAPS will retain the learned PS for the patient so that each time therapy is started the PS will start at the learned PS. The AVAPS algorithm in the BiPAP A40 contains an improvement to more accurately achieve and maintain the target tidal volume. The muscle effort of a spontaneous breath typically results in a larger tidal volume than a machine breath delivered at the same pressure. The new AVAPS algorithm will adjust the pressure slightly on machine delivered breaths to compensate for this difference, and throughout the night, the algorithm will “learn” the correct amount of pressure adjustment to apply to machine triggered breaths. If IPAP Max is reached and the target tidal volume is not achieved, the Low Tidal Volume alarm activates (if enabled).

Product Specifications

Ventilation Modes CPAP, S, S/T, PC, T
Hybrid Ventilation AVAPS (Average Volume Assure Pressure Support)
Weight 2.1kg
Size 21.6cm W x 19cm L x 11.5 cm H
IPAP 4 - 30 cmH2O
EPAP 4 - 25 cmH2O
AVAPS rate 0.5 to 5 cmH2O / min
Inspiratory Time 0.5 - 3 sec
Target Tidal Volume 200 - 1500ml (when AVAPS enabled)
Rise Time 1 (100 ms) - 6 (600 ms)
Breathe rate 0 - 40 
Triggering & Cycling  Digital Auto-TRAK algorithm
Noise Level  < 30dBA at 10 cmH2O 
Alarms Patient disconnection, Apnea, Low minute ventilation, Low tidal volume with AVAPS only), High respiratory rate
Monitoring  Pressure, tidal volume, minute ventilation, respiratory rate, Leak, I/E
Data management Apnea/Hypopnea Index, Obstructed Airway Apnea, Clear Airway Apnea, Hypopnea, Periodic Breathing, RERA, Large Leak and Snore